woodley

"Medical and Laboratory Equipment Solutions"

.

Quote Basket

No quote in basket

ready to proceed?

clear

.

Purchase Online

Purchase Online
.

News

Woodley Equipment Company Inc. Exhibiting at Outsourcing in Clinical Trials West Coast

Woodley Equipment Company is exhibiting at Outsourcing in Clinical Trials West Coast taking place at the Hyatt Regency San Francisco Airport Hotel on 3rd – 4th February 2015.COME AND VISIT US AT BOOTH #43

readmore

Woodley Equipment Company Appointments Dalila Ringland

Woodley Equipment Company is pleased to announce the appointment of Dalila Ringland. Dalila joins the Clinical Trials Division Team at our Hopkinton office near Boston, Massachusetts, USA as Customer Service Representative.

readmore

Woodley Equipment Company Announces the Appointment of Monika Hrdinkova

Woodley Equipment Company is pleased to announce the appointment of Monika Hrdinkova as Office Administrator working for our Clinical Trials Division at our Hopkinton office near Boston, Massachusetts, USA.

readmore

Woodley Equipment Company Exhibiting at Partnerships in Clinical Trials Barcelona

Woodley Equipment is exhibiting at Partnerships in Clinical Trials, which is taking place on 5th to 6th November 2014 at the CCIB, Barcelona, Spain.

readmore

.

View Our Brochure

download-our-brochure
.
Products » Point of Care » i-STAT Portable Clinical Analyser Bookmark and Share
 
<< Previous Product Next Product >>
i-STAT Portable Clinical Analyser

Click here to enlarge

i-STAT Portable Clinical Analyser

 
add to Quote tell-a-friend
Available Documents
Abbott i-STAT Portable Clinical Analyser1.pdf
Abbott i-STAT Portable Clinical Analyser1 PG2.pdf
 
 

The Abbott i-STAT Portable Clinical Analyser is available for rental or hire...

The Abbott i-STAT portable clinical analyser is a true Point Of Care analyser designed to be used at the patient's bedside for critical care tests such as blood gases, electrolytes, metabolites and coagulation. There are a number of cartridges testing different combinations of analytes. This single testing system  eliminates the need for different analysers.

Only a few drops of whole blood are required for testing, between 65 and 95 µl. Samples are processed immediately and provide lab-quality results in 2 minutes making the i-STAT analyser quick and easy to use. 

Features of the i-STAT Portable Clinical Analyser

  • Uses biosensor technology and advanced microfluidics
  • Automatic calibration
  • Fast, reliable lab accurate results in just 2 minutes
  • Portable - battery operated
  • Up to 50 results automatically stored / 5000 in STAT1
  • Minimal maintenance required
  • Small sample size required - just two drops of blood
  • Security features and lockout protocols assure test result integrity
  • Virtually eliminates manual entry errors through integrated bar code scanning (STAT 1 only)
  • The i-STAT analyser provides effortless connectivity with the laboratory via a state-of-the-art data management system or print directly to an external printer
  • Liquid quality controls available
  • Operator and patient ID
  • STAT1 has password protection
  • Wide test menu including:
    • Blood gases
    • Electrolytes
    • Chemistries
    • Coagulation
    • Cardiac markers (cTnI)
    • Haematology

i-STAT Analyser Specification

Display
Dot matrix super twists LCD
Communication link
Infrared transmitter and receiver
Calibration
Factory: electronic, mechanical, thermal, pressure
Power
Two 9V lithium batteries
Operating temperature
16 to 30 °C
Operating humidity
0 - 90% RH
Barometric pressure
300 - 1000 mmHg
Weight
520g
Dimensions
209h x 64w x 52d mm

i-STAT Machine Blood Gas Cartridges

G3+ pH, pCO2, pO2, TCO2, HCO3, BEecf, sO2
CG4+ pH, pCO2, pO2, TCO2, HCO3, BEecf, sO2, Lactate
EG6+ Sodium, Potassium, Haematocrit, Haemoglobin, pH, pCO2, pO2, TCO2, HCO3, BEecf, sO2
EG7+ Sodium, Potassium, Ionised Calcium, Haematocrit, Haemoglobin, pH, pCO2, pO2, TCO2, HCO3, BEecf, sO2
CG8+

Glucose, Sodium, Potassium, Ionised Calcium, Haematocrit, Haemoglobin, pH, pCO2, pO2, TCO2, HCO3, BEecf, sO2

i-STAT Machine Chemistry Cartridges

G Glucose
Crea Creatine
E3+ Sodium, Potassium, Haematocrit, Haemoglobin
EC4+ Glucose, Sodium, Potassium, Haematocrit, Haemoglobin
6+ Urea Nitrogen, Glucose, Chloride, Sodium, Potassium, Haematocrit, Haemoglobin
EC8+ Urea Nitrogen, Glucose, Chloride, Sodium, Potassium, Haematocrit, Haemoglobin, pH, pCO2, TCO2, HCO3, BEecf, Anion Gap

i-STAT Machine Coagulation Cartridges

ACT (Celite)® ACT (Celite)®
ACT (Kaolin) ACT (Kaolin)
PT/INR PT/INR

i-STAT Cardiac Marker Cartridge

cTnI Troponin I

Calculated tests: TCO2, HCO3, BEecf, sO2, Anion Gap, Haemoglobin

This highly advanced technology, combined with Woodley Equipment's in-house biomedical scientists and medical electronics specialists, provides the ultimate combination of patient testing for your clinical trial.

This Abbott i-STAT Portable Clinical Analyser is available for hire/rent for your clinical trial. It can be ordered with any other clinical trial, medical or laboratory Equipment to create the most effective equipment management solution for your study.

Prices 

The Abbott i-STAT is currently available on a rental basis - please use the links at the top of the page to request a quotation

 

Specialists in i-STAT hire/rental and i-STAT management

 